Scientific Letter
Open Access
Non-invasive inhaled nitric oxide in term and preterm newborns: A therapeutic option in selected patients
Óxido nítrico y ventilación no invasiva en neonatos. Posibilidad terapéutica en pacientes seleccionados
Visits
2368
Carlos Morell Úbedaa,
Corresponding author
carlos.morell@hotmail.com

Corresponding author.
, Juan Diego Toledo Parreñoa,b, Antonio Pérez Iranzoa
a Unidad Cuidados intensivos pediátricos y Neonatales, Hospital General Universitari Castelló, Castelló de la Plana, Spain
b Servicio de Neonatología, Hospital Universitari y Politécnic La Fe, Valencia, Spain
This item has received

Under a Creative Commons license
Article information
Full Text
Bibliography
Download PDF
Statistics
Tables (1)
Table 1. Clinical characteristics and outcomes of patients treated with inhaled nitric oxide through non-invasive ventilation.
Full Text
Dear Editor:

The administration of inhaled nitric oxide (iNO) has proven effective for treatment of persistent pulmonary hypertension of the newborn (PPHN) in neonates born to term of after 34 weeks of gestation.1–3 In preterm neonates born before 34 weeks of gestation, the use of iNO is controversial, although its off-label use as rescue therapy has been increasing in clinical practice.2 Until a few years ago, iNO was administered exclusively through invasive mechanical ventilation, with the risks that this approach involves, especially in preterm infants. Therefore, given the current preference for minimally invasive respiratory support, it may be worth considering the option of administering iNO through non-invasive ventilation devices (iNO-NIV).3,4

In a period of 4 years, 8 patients with gestational ages ranging from 25 to 41 weeks and birth weights from 900 to 3700 g received iNO-NIV in our unit. Table 1 summarises the clinical characteristics and outcomes of the patients. The inclusion criteria were: need of a fraction of inspired oxygen (FiO2) greater than 60%; normocapnia in NIV (capillary partial pressure of carbon dioxide [pCO2] < 55 mmHg); haemodynamically stable (normal heart rate, blood pressure and serum lactate for gestational age and weight); suspected PPHN with a difference between preductal and postductal saturations greater than 10% and/or compatible findings of echocardiography at admission (estimated pulmonary pressure in relation to the patent ductus arteriosus or tricuspid regurgitation pressure gradient and/or deviation of the interventricular septum). The exclusion criteria were: air leak, severe apnoea of prematurity, pH < 7.25 or any other absolute indication for mechanical ventilation.

Table 1.

Clinical characteristics and outcomes of patients treated with inhaled nitric oxide through non-invasive ventilation.

Patient 
Gestational age (weeks + days)  33+1  36+2  38+0  31+5  25+2  41+1  40+2  37+0 
Weight (grams)  1415 g  2795 g  2415 g  1490 g  900 g  3575 g  3680 g  2680 g 
Gestational and perinatal history  - Oligoamnios- Urgent caesarean due to abnormal CTG and reversed end-diastolic flow-No antenatal steroids-Apgar 6/8. Resuscitation with PPV and FiO2 of up to 100%.- Immediate increased work of breathing  -Preeclampsia and gestational diabetes -Urgent caesarean due to placental abruption-Apgar 4/6. Resuscitation with PPV and FiO2 of up to 100%.- Immediate increased work of breathing  - Normal vaginal delivery. Light meconium-stained fluid- Apgar 9/9- Admitted to neonatal unit with cyanosis (SatO2: 80−85%). Normal hyperoxia test  -Premature rupture of membranes and preterm labour- Antenatal steroids- Apgar 7/8. Resuscitation with PPV and FiO2 of up to 60%- Immediate increased work of breathing  - Premature rupture of membranes. Cervical incompetence- Caesarean section- Antenatal steroids- Apgar 4/7. Resuscitation with PPV and FiO2 of up to 100%.  - Urgent caesarean due to abnormal CTG.- Meconium-stained fluid- Resuscitation with PPV and FiO2 of up to 100%.- Immediate increased work of breathing  - Urgent caesarean due to abnormal CTG- Meconium-stained fluid- Apgar 3/8/8- Resuscitation with PPV and FiO2 of up to 100%. Cardiac massage for 30 s- Immediate increased work of breathing  - Premature rupture of membranes- Caesarean due to breech presentation- Apgar 9/10- Progressive increase in work of breathing and hypoxaemia 
Diagnostic tests at admission  - RX: HMD- Echo: dilated right heart chambers and paradoxical septal motion (right-left). TI. PDA. PP not estimated  - RX: cardiomegaly. Normal lung parenchyma-Echo: thickened septum. TI. PDA with estimated PP of 45−50 mmHg  - RX: normal- Echo: 2 mm VSD with left-right shunt and estimated PP of 35−40 mmHg. PDA  - RX: HMD- No echo  - RX: HMD- Echo: PDA. TI with an estimated PP of 40−50 mmHg  - RX: Meconium aspiration- Echo: TI a d PDA with estimated PP of 55−65 mmHg  - RX: meconium aspiration- Echo: dilated right heart chambers and paradoxical septal motion (right-left). PDA. TI with estimated PP of 55−65 mmHg  - RX: HMD- Echo: dilated right heart chambers and paradoxical septal motion (right-left). TI. PDA. PP not estimated 
Initial respiratory support  - BiPAP (MAP: 6 cmH2O)- Surfactant (LISA)  - CPAP (5 cmH2O)  - CPAP (5 cmH2O)  - BiPAP (MAP: 6 cmH2O)- Surfactant (LISA), no improvement  - BiPAP. (MAP: 6−7 cmH2O)- Surfactant (LISA)  - BiPAP (MAP: 6−7 cmH2O)  - CPAP (MAP: 6 cmH2O)  -CPAP (MAP 6 cmH2O)- Surfactant (LISA) 
MAP (mmHg)  33  37  40  35  32  60  65  55 
Pre- to post-ductal difference (%)  10  15  10  10  10  10−12  10−12 
FiO2 pre-iNO  60−70%  100%  90%  60%  70%  80%  80  60% 
Dose of iNO-NIV and outcome  - 10 ppm- Reduction to FiO2 25% in 1 h- Gradual removal of iNO in 24 h  - 20 ppmReduction to FiO2 21% in 2 h- Gradual removal over 24 h  - 20 ppmReduction to FiO2 21% in 2 h- Gradual removal over 24 h  - 10 ppmReduction to FiO2 21% in 2 h- Gradual removal over 24 h  - 5 ppm, no response−10 ppm: Reduction to FiO2 21% in 2 h- Gradual removal over 36 h  - 20 ppm- Transient reduction to FiO2 of 60%- Mechanical ventilation due to hypoxaemia at 6 h post birth.- HFOV and inotropic agents-No difference in pre-postductal saturations after 15 h. Gradual removal of iNO over 72 h  - 20 ppm- Transient reduction to FiO2 50%- Mechanical ventilation due to hypoxaemia and hypercapnia at 48 h post birth- HFOV and inotropic agents- No difference in pre-postductal saturations after 24 h. Gradual removal of iNO over 72 h  - 20 ppm- Reduction to FiO2 30% in 6 h- Gradual removal over 30 h 

BiPAP, bi-level positive airway pressure system; CPAP, continuous positive airway pressure; CTG, cardiotocography; Echo, echocardiogram; HMD, hyaline membrane disease; FiO2, fraction of inspired oxygen; HFOV, high-frequency oscillatory ventilation iNO, inhaled nitric oxide; LISA, less-invasive surfactant administration; MAP, medium airway pressure; PDA, patent ductus arteriosus; PP, pulmonary pressure; PPV, positive-pressure ventilation; RX, X-ray; SatO2, oxygen saturation; TI, tricuspid insufficiency.

The source of iNO was the INOvent® delivery system (INO Therapeutics, Datex-Ohmeda Inc, Madison, WI, USA) with INOmax® 800 ppm cylinders. Non-invasive ventilation was delivered with the Infant Flow SiPAP® system (Vyasis™ Healthcare, Bird Products, Palm Springs. CA, USA). Previous studies have found the use of these devices for administration of iNO-NIV safe.4

Our patients with PPHN responded quickly and optimally to iNO-NIV, with a quick descent in oxygen requirements, and none required mechanical ventilation during the stay. Our results were similar to those reported by Sahni et al.3 in patients of comparable characteristics (haemodynamically stable PPHN with normal pH). It seems reasonable to hypothesise that early administration of iNO-NIV could prevent clinical worsening in these cases, in addition to the use of a high FiO2 for prolonged periods.1,5 However, in the 2 patients with pulmonary hypertension secondary to meconium aspiration syndrome the response was less favourable and mechanical ventilation could not be avoided. Less favourable outcomes have also been observed in patients with meconium aspiration syndrome in other case series,3 probably due to the high prevalence of pulmonary disease intrinsic to this condition. Therefore, the correct identification of patients that may benefit from iNO-NIV is key, and ultrasound may be very helpful for this purpose.6 Seven of our patients had indirect signs of pulmonary hypertension at treatment initiation.

Doses of 5–20 ppm proved sufficient in our patients, without an associated increase in nitrogen dioxide or methaemoglobin.4,5 In theory, iNO acts as an antiplatelet agent, but we found no evidence of an association with an increased incidence of interventricular haemorrhage or necrotising enterocolitis in the reviewed literature.2,5 No direct adverse effects were observed during treatment. There was only 1 case of patent ductus arteriosus that required surgical correction, but it occurred in an extremely preterm infant and in association with clinically significant sepsis in the second week of life. Previous studies have not found an increase in the incidence of persistent patent ductus arteriosus or pulmonary haemorrhage with the use of iNO, although its effects on the pulmonary circulatory system of preterm infants should be evaluated in future studies on this treatment.

In conclusion, early use of iNO-NIV could be an adequate alternative in selected cases of PPHN with hypoxaemia, without hypercapnia and in haemodynamically stable patients. These patients could benefit from the avoidance of sedation, intubation, mechanical ventilation and delivery of high oxygen concentrations and their potential complications, something that can be even more important in preterm infants. Randomised trials in larger samples are needed to obtain rigorous conclusions.

References
[1]
K.J. Barrington, N. Finer, T. Pennaforte, G. Altit.
Nitric oxide for respiratory failure in infants born at or near term.
Cochrane Database Syst Rev, (2017),
[2]
N. Finer, N. Evans.
Inhaled nitric oxide for the preterm infant: evidence versus practice.
Pediatrics, 135 (2015), pp. 754-756
[3]
R. Sahni, X. Ameer, K. Ohira-Kist, J.T. Wung.
Non-invasive inhaled nitric oxide in the treatment of hypoxemic respiratory failure in term and preterm infants.
J Perinatol, 37 (2017), pp. 54-60
[4]
R. Lindwall, M. Blennow, M. Svensson, B. Jonsson, E. Berggren-Boström, M. Flanby, et al.
A pilot study of inhaled nitric oxide in preterm infants treated with nasal continuous positive airway pressure for respiratory distress syndrome.
Intensive Care Med, 31 (2005), pp. 959-964
[5]
J. Kinsella, R. Steinhom, Krishnan, J. Feinstein, I. Adatia, E. Austin, et al.
Recommendations for the use of inhaled nitric oxide therapy in premature newborns with severe pulmonary hypertension.
JPeds, 170 (2016), pp. 312-314
[6]
D. Shah, M. Kluckow.
Early functional echocardiogram and inhaled nitric oxide: Usefulness in managing newborns born following extreme preterm premature rupture of membranes (PROM).
J Paediatr Child Health, 47 (2011), pp. 340-345

Please cite this article as: Úbeda CM, Parreño JDT, Iranzo AP. Óxido nítrico y ventilación no invasiva en neonatos. Posibilidad terapéutica en pacientes seleccionados. An Pediatr (Barc). 2022;96:161–164.

Idiomas
Anales de Pediatría (English Edition)
Article options
Tools
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?